The current Right Ascension movement rate offset for telescope guiding (degrees/sec)

Namespace: ASCOM.DeviceInterface
Assembly: ASCOM.DeviceInterfaces (in ASCOM.DeviceInterfaces.dll) Version: 6.0.0.0 (6.1.1.2619)

Syntax

C#
double GuideRateRightAscension { get; set; }
Visual Basic
Property GuideRateRightAscension As Double
	Get
	Set
Visual C++
property double GuideRateRightAscension {
	double get ();
	void set (double value);
}

Remarks

This is the rate for both hardware/relay guiding and the PulseGuide() method.

This is only available for telescope InterfaceVersions 2 and 3

NOTES:

  • To discover whether this feature is supported, test the CanSetGuideRates property.
  • The supported range of this property is telescope specific, however, if this feature is supported, it can be expected that the range is sufficient to allow correction of guiding errors caused by moderate misalignment and periodic error.
  • If a telescope does not support separate guiding rates in Right Ascension and Declination, then it is permissible for GuideRateRightAscension and GuideRateDeclination to be tied together. In this case, changing one of the two properties will cause a change in the other.
  • Mounts must start up with a known or default right ascension guide rate, and this property must return that known/default guide rate until changed.

Exceptions

ExceptionCondition
PropertyNotImplementedExceptionIf the property is not implemented
InvalidValueExceptionIf an invalid guide rate is set.